Many Bromley homes can keep some or all existing radiators when they switch to a heat pump. A room-by-room survey sorts each radiator into keep, adjust or replace, so you pay only for rooms that need work. The £7,500 Boiler Upgrade Scheme grant applies either way, and the installer claims it for you.

When a heat pump can keep your existing radiators

A heat pump with existing radiators works when each radiator gives out enough heat at a lower water temperature. The question “Do I need new radiators for a heat pump?” gets a room-by-room answer: new units go where the calculation shows a shortfall. The Energy Saving Trust says heat pumps commonly send water to radiators at between 35 and 45°C. A room-by-room heat loss calculation shows which radiators already cope, which need a small change and which need replacing.

Some homes keep every radiator. Others need two or three changed. A few need a full set.

Heat pump flow temperature sets the radiator size

A gas boiler commonly sends water to radiators at 65 to 75°C. A heat pump runs cooler because its efficiency rises as the water temperature falls.

Radiators are rated with water 50°C hotter than the room (the BS EN 442 test condition, written ΔT50). Run one cooler, and its output drops faster than the temperature does.

Here is the arithmetic for two rooms. The figures are illustrative and assume a 50°C flow, 40°C return and 21°C room.

Room Heat loss Radiator rating Output at 50°C flow Verdict
Bedroom 700 W 1,900 W about 730 W Keep
Living room 1,500 W 2,000 W about 770 W Upgrade

The bedroom radiator copes. The living room radiator delivers about half of what the room loses, so that room needs a larger or finned unit. A higher flow temperature can let more existing radiators stay, and the heat pump then uses more electricity. Every design has to weigh that trade-off.

Keep, adjust or replace: a three-way radiator check

A useful survey sorts every radiator into one of three groups.

  • Keep. Output at the design flow temperature meets the room’s heat loss. Double-panel convector radiators in well-insulated rooms often qualify.
  • Adjust. The shortfall is modest. Swapping a single panel for a double or triple panel adds output without needing more wall space. A fan-assisted unit or extra insulation closes small gaps.
  • Replace. The shortfall is large, such as a small single panel under a big window. These rooms need a heat pump radiator upgrade to larger units sized from the calculated heat loss.

Low temperature radiators for heat pumps are ordinary radiators with more surface area or more panels. Heat pump radiators in the UK need no special technology.

Ways to keep more of what you have

Cutting heat loss shrinks the radiator requirement. Loft insulation and draught-proofing lower each room’s figure, so an existing radiator covers the room at a lower temperature. Balancing the system and flushing sludge restores lost output.

Pipework is the constraint people overlook. A heat pump moves up to four times the water a boiler does for the same heat, because its temperature drop is around 5°C against a boiler’s 20°C. Narrow pipes to a far bedroom can restrict flow. That decides heat pump radiator compatibility as much as radiator size does.

What a heat pump installation survey should cover

The survey produces the numbers behind every decision above. Ask for:

  • A room-by-room heat loss calculation, with wall, window, floor and loft details recorded for each room
  • Radiator type, size and panel count, with output at the proposed flow temperature
  • Pipework sizes and routes
  • Cylinder location, outdoor unit position and electrical supply capacity

Ask for the result as a written design that names the flow temperature, gives a verdict for each radiator and itemises any upgrade.

The installer completes the Boiler Upgrade Scheme application on your behalf, so grant-funded work goes through an MCS-certified heat pump installer. Look up the company’s certificate number on the MCS website before you sign anything.

Heat pump grants for Bromley homeowners

Boiler Upgrade Scheme

The Boiler Upgrade Scheme gives £7,500 towards an air source heat pump in England and Wales. The amount is the same for an air source heat pump with existing radiators or with upgraded ones. Eligible oil or LPG homes can claim £9,000 from 21 July 2026 to 31 March 2027. Your installer claims the grant, and your final invoice shows the reduced amount.

Warm Homes: Local Grant

Bromley Council lists the Warm Homes: Local Grant for low-income households in homes rated EPC D or lower, and it funds works including insulation and air source heat pumps. Check eligibility on the council’s grants page.

Air-to-air systems

A £2,500 grant applies to air-to-air heat pumps. These warm rooms with indoor fan units, so radiators play no part. Scheme amounts and dates change, so Proton confirms the current grant value during your survey. To see which of your own radiators can stay, book a heat pump survey with Proton.

How Proton approaches a radiator survey

Proton Energy Solutions designs heat pump systems around the property. Proton surveys homes across Bromley, Surrey, Greater London and Kent, runs the heat loss calculation for every room and reports each radiator as keep, adjust or replace. Where a home has solar PV or battery storage, the design can account for it.

When you replace a boiler with a heat pump, keeping radiators is realistic if the numbers support it, and the numbers come from your own rooms.

Frequently asked questions

  1. Can I get a heat pump without changing my radiators?
    Yes. A heat pump works with your existing radiators when each one gives out enough heat at the lower flow temperature. A room-by-room heat loss calculation confirms which radiators can stay in place.
  2. Do I need new radiators for an air source heat pump?
    Only in rooms where the existing radiator falls short. An air source heat pump runs radiators at 35 to 45°C, so a survey compares each radiator’s output with its room’s heat loss and flags upgrades.
  3. Can I use my existing radiators with a heat pump?
    Yes, where their output at heat pump temperatures covers the room’s heat loss. Larger double-panel radiators often manage, and small single panels are usual candidates for an upgrade to a bigger one.
  4. Will a heat pump work with my current radiators?
    It will run, and comfort depends on radiator output. If a radiator gives out less heat than the room loses at the design flow temperature, the room stays cool and needs a larger radiator or insulation.
  5. Do heat pumps need special radiators in the UK?
    Heat pumps need no special radiator type. Any radiator works if it gives out enough heat at 35 to 45°C, which usually means more surface area, such as a double or triple panel convector in the room.
  6. Which radiators work best with a heat pump?
    Double and triple panel convector radiators give high output for their wall space. Fan-assisted radiators suit rooms with little wall area, and oversized units run well at low flow temperatures too.
  7. Do I need to replace all my radiators for a heat pump?
    Often only some. A survey sorts radiators into keep, adjust or replace. Well-insulated homes, or homes with large radiators, may need few changes, while others need several rooms upgraded in full.
  8. How do I know if my radiators are suitable for a heat pump?
    Compare each radiator’s output at the planned flow temperature with its room’s heat loss. If the output meets or exceeds the loss, the radiator suits a heat pump. A heat pump survey checks this for you.
  9. What is a room-by-room heat loss calculation for a heat pump?
    It estimates how much heat each room loses on a cold design day, based on walls, windows, floors, roof and ventilation. The result sizes the heat pump and sets the output each radiator must deliver.
  10. Can I replace my gas boiler with a heat pump and keep my radiators?
    Yes, many homes keep some or all radiators. Radiator output at the heat pump’s flow temperature decides, and a survey confirms which stay. Your installer claims the Boiler Upgrade Scheme grant for you.