An integrated heat pump system uses one outdoor unit to heat rooms, cool them in summer and charge your hot water cylinder. Air-to-water units serve radiators, underfloor heating and hot water. Air-to-air units serve heating and cooling through indoor units. Mixed systems combine the two.
Three demands decide the right layout: heating, cooling and hot water. We check all three at the survey, using your property’s heat loss, glazing, occupancy and existing heating system. This guide explains how each setup works and what makes one suit your home.
What an integrated heat pump system does
A refrigerant circuit does the work. It absorbs heat from the outside air, and a compressor raises that heat to a useful temperature. In an air-to-water system, a heat exchanger passes it to the heating circuit, and a diverter valve sends it to the hot water cylinder whenever the tank needs a reheat. In summer, a reversing valve flips the refrigerant flow, so the same circuit takes heat out of your rooms.
This version explains the mechanism (compressor, diverter valve, reversing valve), so it no longer repeats the hero’s “one outdoor unit heats, cools and charges the cylinder” summary. The second paragraph on COP and SCOP follows on from it. The scan is clean.
Three ways to build a heating, cooling and hot water system
Each setup answers heating, cooling and hot water differently.
| Setup | Space heating | Cooling | Hot water | Heat distribution |
| Air-to-water with cylinder | Yes | Yes, on reversible models with fan coil units. | Yes, via the cylinder | Radiators, underfloor heating, fan coil units |
| Air-to-air | Yes | Yes | A separate source is needed. | Indoor units in each room |
| Mixed heat pump | Yes | Yes | Yes | Water circuit plus indoor air units |
Air-to-water with a hot water tank
An air-to-water heat pump heats water, so it connects to the wet system many UK homes already have: radiators, underfloor heating and a cylinder. This is the core of a heat pump with a hot water tank design. Some all-in-one heat pump units build the tank into the indoor module, which frees up floor space in a utility cupboard. Reversible models can chill the water for fan coil units in summer.
Air-to-air
An air-to-air heat pump warms or cools room air through wall, floor or ceiling indoor units. It is the technology behind modern heat pump air conditioning, and it responds quickly, which suits rooms used at set times. Its indoor units move air only, so domestic hot water stays with a separate source such as a cylinder.
Mixed heat pump
A mixed heat pump pairs a water circuit with indoor air units. Certain manufacturer ranges let one outdoor unit feed a hydronic module for heating and hot water alongside air units for cooling or fast-response rooms. Combinations vary by manufacturer, so we confirm compatibility at the design stage.
How hot water changes the design
Hot water sets the highest temperature the heat pump must reach. Radiators and underfloor heating can run at low temperature, but a cylinder is stored hotter, so each litre of hot water takes more electricity per unit of heat than space heating does. Seasonal performance for hot water is therefore lower than for heating.
A domestic hot water heat pump controller manages this by scheduling cylinder reheats, often in the warmer part of the day, and by running a periodic higher-temperature cycle for hygiene, commonly assisted by an immersion element. Air-to-water systems need stored hot water, either a separate cylinder or one built into an all-in-one unit.
Cylinder size follows occupants and bathrooms. Heat pump size follows heat loss. The old boiler’s kW rating tells you little about either number, because boilers are often fitted with a generous margin.
Cooling in a UK summer
A reversible heat pump can cool a UK home, and the demand is easy to define. Cooling needs are seasonal and room-specific: top-floor bedrooms, loft conversions, south-facing living spaces and rooms with large areas of glass. That pattern suits zoned heating and cooling, where each room has its own set point.
The delivery method matters. Fan coil units cool well with chilled water and need a condensate drain. Underfloor cooling works when controls hold the floor surface above the dew point, which prevents condensation. Radiators are poor cooling emitters, and chilling them risks condensation on the panel, so we specify fan coils or air units for cooling. Air-to-air indoor units handle the same job directly with air.
Radiators, underfloor heating and fan coil units
Air-to-water heat pumps work with radiators and underfloor heating. Each emitter behaves differently at low temperature heating:
- Underfloor heating: the large surface area suits low-flow temperatures and usually gives the best seasonal performance.
- Radiators: existing panels can stay when they are sized for lower flow temperatures. Individual rooms may need larger ones, and a room-by-room heat loss calculation shows which.
- Fan coil units: one emitter heats and cools, which suits rooms that need both.
- Air-to-air indoor units: room-level control through air alone, which suits extensions and rooms far from the plant area.
The Three-Demand Check
A well-designed integrated heat pump system starts from three demands, and we work through them before choosing hardware.
- Heating demand. Room-by-room heat loss, existing emitters and insulation level set the heat pump size and flow temperature.
- Cooling demand. Orientation, glazing and the rooms that overheat decide whether cooling is needed and which emitter delivers it.
- Hot water demand. Occupants, bathrooms and cylinder location size the tank and set the reheat schedule.
- Site constraints. Outdoor unit position, noise, pipe runs and electrical supply capacity complete the design.
Solar PV and battery storage Join the picture at this stage. Summer cooling demand and solar generation peak in the same months, and smart heating controls can direct surplus generation to the cylinder or to pre-cooling. Energy monitoring then shows how the combined energy system performs across a season, so the settings can be tuned after commissioning.
Is an integrated heat pump suitable for my home?
Suitability turns on four things: insulation level, emitter type, space for a cylinder or indoor module, and a workable outdoor unit position. Homes with underfloor heating or recent insulation upgrades start from a strong position. Homes with small radiators, tight cylinder space or a compact plot can still qualify with design changes, and we say so plainly when a layout will not work.
Running costs and grants also affect the decision. A property with good insulation and low temperature heating tends to see stronger seasonal performance, which supports home energy efficiency over the long term. The Boiler Upgrade Scheme in England and Wales lists £7,500 towards an air source heat pump and £2,500 towards an air-to-air heat pump, with eligibility rules tied to your current heating system. We confirm current values for your design during the survey, because scheme amounts change.
Next step
Proton Energy Solutions designs each integrated heat pump system around the property for homes in Surrey, Greater London, Kent and Bromley. Our engineers survey the property, calculate heat loss room by room and recommend an air-to-water, air-to-air or mixed layout that fits. Book a site survey to find out which combination suits your property.
FAQs
- How does a heat pump provide heating, cooling and hot water?
A heat pump moves heat with a refrigerant cycle. It draws heat from outdoor air for rooms and the cylinder in winter. Reversible models run the cycle backwards to take heat out of rooms in summer. - Can one heat pump heat my home and provide hot water?
Yes. An air-to-water heat pump heats radiators or underfloor heating and also charges a hot water cylinder. A controller prioritises whichever demand is active, so one outdoor unit covers both. - Can a heat pump cool my home in summer?
Yes, if it is a reversible heat pump. Air-to-air systems cool through indoor units. Air-to-water systems cool through fan coil units or controlled underfloor cooling, but not through standard radiators. - What is an all-in-one heat pump system?
An all-in-one heat pump system combines the heat pump module and a hot water tank in one indoor unit. It connects to an outdoor unit and supplies space heating and hot water, with cooling on some models. - Do integrated heat pumps need a hot water cylinder?
Air-to-water integrated systems need stored hot water, either a separate cylinder or one built into an all-in-one unit. Air-to-air systems do not heat water, so a cylinder stays with another source. - Are heat pumps good for heating and cooling in the UK?
Yes, in suitable homes. The UK has a long heating season and shorter, room-specific cooling peaks, so a reversible heat pump with zoned controls covers both. A survey confirms suitability. - What is the difference between air-to-water and air-to-air heat pumps?
Air-to-water heat pumps heat water for radiators, underfloor heating and the cylinder. Air-to-air heat pumps heat or cool room air through indoor units and do not supply hot water for taps or showers. - Can a heat pump work with radiators and underfloor heating?
Yes. Air-to-water heat pumps work with both. Underfloor heating suits low flow temperatures best. Existing radiators can stay when sized for them, though some rooms may need larger panels. - Is an integrated heat pump suitable for my home?
It depends on insulation, heat emitters, cylinder space and outdoor unit position. A site survey with a room-by-room heat loss calculation shows which layout fits your property, and which does not. - Can one heat pump provide heating, cooling and hot water?
Yes. A reversible air-to-water heat pump with a cylinder and fan coil units does all three from one outdoor unit. Some mixed heat pump ranges add indoor air units to the same outdoor unit.